0

Incorrect manual charging calc TMY 2022 LR


S
Stephen

Hi,
To compensate for a missing new supercharger I have added a mnual charge point 130 kW in 30 mints.
The charge only shows an increase in SOC from 32-37%.
This compared to the ABRP added chargepoint below 6 mints giving 12%-28% SOC.


A

Activity Newest / Oldest

Avatar

Katya_ABRP

Status changed to: Closed

Avatar

Katya_ABRP

Status changed to: User Feedback

Avatar

Katya_ABRP

Hi Stephen,

We shouldn't be missing any Tesla Superchargers. New ones are added latest 24 hours after being opened, usually much faster.

Please make sure you've enabled 'Tesla CCS' among the options for 'Fast chargers' in: Settings (advanced) > Chargers & Networks > Fast chargers, as most new locations are CCS only.

Regarding the charging speed, please attach a link to the plan. You can generate a link by clicking: share > share ABRP link.

/Katya


  • S
S

Stephen

Hi Katya,

The missing charger is the UNO-X i pointed out in a separate post that You mentioned You already added. :-)
Here is a link to a similar route plan that I just created. Again the issue is there with incorrect effect of 30 mints charging: abetterrouteplanner.com/?plan_uuid=6234b4a1-20a9-4857-a870-55724af037aa

/Stephen


S

Stephen

Hi Katya,
Any news on this item?
/Stephen


Avatar

Katya_ABRP

Hi Stephen,

The issue with the above linked plan is that the charger you edited is a slow charger. To make a workaround for this, add a charging session to a normal waypoint:

abetterrouteplanner.com/?plan_uuid=2fc1c2a8-3f71-4d90-b972-8899d56d2bb5

My colleague was the one who replied in the other thread but I can take a 2nd look at that UNO-X charger. I take it you're still missing it?

/Katya


S

Stephen

Hi again Katya,
Well regardless I am overwriting with a power specification and a duration, thus it should ignore the default data regarding the charger.


S

Stephen